New Product Release | TS3004: 8-Channel Thermocouple Acquisition Device

In the field of industrial measurement, accurately acquiring temperature data often involves cumbersome signal processing and complex system integration. TOSUN's newly launched TS3004 High-Performance Thermocouple Temperature Acquisition Deviceby leveragingIntegrated design featuring 8-channel K-type thermocouple inputs, built-in high-precision cold junction compensation, and direct Celsius output.TS3004 dramatically simplifies the signal chain, eliminating the need for manual calculations and external compensation.Achieve true “plug-and-play functionality”.

Hardware Products 20251216 3 Thermocouple Acquisition Equipment

TS3004 is a high-performance thermocouple temperature acquisition device launched by TOSUN.Built-in high-precision cold junction compensation circuit supports digital processing of 8-channel K-type thermocouple signals, directly outputting temperature data in degrees Celsius (℃). The measurement range spans -200°C to 1370°C, with input terminals capable of withstanding ±45V overvoltage surges.

Hardware Products 20251216 2 Thermocouple Acquisition Equipment

The device utilizes a D-Sub 9-pin interface for communication with other CAN bus type devices. When paired with the powerful TSMaster software, it supports loading DBC database files, enabling convenient monitoring, analysis, and simulation of CAN FD bus data.


High-precision measurement: Built-in cold junction compensation, direct output in degrees Celsius

  • Built-in cold junction compensation, directly outputs temperature in degrees Celsius
  • Supports temperature measurement from -200°C to 1370°C, withstands ±45V overvoltage
  • The standard version supports K-type thermocouples (J, N, R, S, T, E, and B types available upon request).
  • Supports 50 Hz line frequency filtering (60 Hz available upon request), featuring sensitive thermocouple fault detection.

Select operating mode via the 4-digit hardware ID DIP switch:

  • Default Mode (ID 0–14)
    After power-up, the CAN baud rate is fixed at 1 Mbps. The device supports configuration messages sent via communication commands. Upon receiving a message, the corresponding configuration parameters are stored in memory.
  • Custom Mode (ID 15)
    Upon power-up, the system automatically loads the most recently stored CAN configuration parameters (such as baud rate, filter settings, etc.). Configuration messages cannot be sent via communication commands in this mode.

Specifications

Basic parameters
ConnectorStandard D-Sub, 9-pin
Electricity SupplyPhoenix Terminal Power Supply
Power Wastage1.5 W
ESD ProtectionContact discharge rating: 4 kV Air discharge rating: 8 kV
Housing Materialmetals
Sizes150 × 97.6 × 72 mm
Weights422.6 g
Operating Temperature RangeTo Be Announced
Operating Humidity Range10%~90% (no condensation)

CAN (Default Mode)

Basic parameters
CAN Connection StandardHigh-Speed CAN Connection (Compliant with ISO 11898-2 Specification)
Supported ProtocolsFully supports the CAN protocol (compliant with ISO 11898-1 specifications)
CAN Baud RateFixed 1 Mbps communication baud rate
Sampling point82.5%
CAN Frame Data LengthMaximum length supports 8-byte extended data frames
Terminating ResistorsThe CAN channel includes a built-in 120Ω terminating resistor, which can be configured via hardware DIP switches.

CAN (Custom Mode)

Basic parameters
CAN Connection StandardHigh-Speed CAN Connection (Compliant with ISO 11898-2 Specification)
Supported ProtocolsFully supports CAN and CAN FD protocols (compliant with ISO 11898-1 specifications)
CAN Baud RateAdjustable from 125 kbps to 1 Mbps
CAN Frame Data LengthUp to 8 bytes
CAN FD Baud RateAdjustable from 125 kbps to 8 Mbps
CAN FD Frame Data LengthSupports 3-byte and 16-byte data frames, supports BRS frame type
Terminating ResistorsThe CAN channel features a built-in 120 Ω termination resistor, configurable via hardware DIP switches.
Bus-Off Self-RecoveryAutomatic recovery is disabled by default. Self-recovery commands can be issued in default mode.

Functionality

Basic parameters
Collect K-type thermocouple temperatureDigitally process the acquired signals and output in degrees Celsius (℃).
Cold-end compensationBuilt-in cold junction compensation
Switch work modeHardware DIP Switch Settings: Default Mode, Custom Mode
Fault ManagementWhen multiple fault codes are present, display the fault code with the highest value.
Overvoltage Protection±45 V
Interference resistance50 Hz (60 Hz available upon request)
Temperature measurement range-200°C to 1370°C
Linear errorTo Be Announced

* The device supports ±45 V input overvoltage protection. If interference exceeding ±45 V is introduced in the operating environment, contact us to modify the circuit for enhanced protection capability (circuit modification will increase offset voltage, affecting measurement accuracy).

Power Supply Specifications

ParametersTest ConditionsMinimum ValueTypical ValueMaximum ValueUnit
Operating VoltagePhoenix Terminal Power Supply912.036V
Power WastagePhoenix Terminal Power Supply1.5W

CAN Interface Specifications

ParametersTest ConditionsMinimum ValueTypical ValueMaximum ValueUnit
Terminating ResistorsEnable120Ω
Disable
Isolation Withstand VoltageInsulation Resistance Tester2500VDC

EMC (Electromagnetic Compatibility) Performance Parameters

Test ItemsStandardTest ConditionsLevelUnit
ESDIEC 61000-4-2Contact Discharge±4kV
Air Discharge±8kV
EFTIEC 61000-4-4Group Pulse±2kV

Get an Early Look! Apply Now for the TS3004 New Product Trial

Simplify temperature acquisition with the new TS3004 now available for trial. Experience 8-channel, direct-read °C, and ±45V overvoltage protection for one-stop high-precision temperature measurement. We invite you to participate.

Apply for a trial

If you want to know more about TOSUN hardware products, you can fill out the application form and we will contact you as soon as possible.